For quickly determining
the buckling load, the same result can be calculated by means of the following
formula:

PB = Buckling
load [N]
dN = Nominal diameter of ballscrew [mm]
ls = Length of unsupported shaft [mm]
m = Coefficient of bearing configuration
fixed - fixed: 22,4 (1)
fixed - supported:
11,2 (2)
supported - supported: 5,6 (3)
fixed - free: 1,4 (4)
For safety reasons,
a factor of 0.5 must be applied:
|