9414/12.40A.9.9

Description

  • Nut Series 9414 with Z-ball return, Flange single nut, 3 ball circles per deflector
  • Available with or without wipers
  • Nut shape design for transmission of high loads
  • Single start ball thread, ground execution according to accuracy class P1-P5
  • For appropriate nut design we need direction of main load. In case of tensile load, please check tensile strength of mounting screws.

Technical Data and Dimensions

Series
9414
Flange thickness
[mm]
L7
18
Nominal diameter
[mm]
dN
40
Max. axial load
[kN]
Fmax
113,4
Lead
[mm]
P
12
Dynamic load capacity
[kN]
Ca
226,80
Ball circles
i
3x3
Static load capacity
[kN]
C0a
440,00
Ball diameter
[mm]
dW
9
Pilot diameter
[mm]
D1
70
DN-value
160000
Bolt circle diameter
[mm]
D4
86
No. of starts
1
Flange hole diameter
D5
9
Maximum play
[mm]
0,02
Flange diameter
[mm]
D6
104
Nut length
[mm]
L
152
Contact E-Mail

Contact

August Steinmeyer GmbH & Co. KG
Riedstr. 7
72458 Albstadt

Telefon +49 7431 1288-0
E-Mail info@steinmeyer.com

Service Hotline

Telefon +49 7431 1288-200*
E-Mail service@steinmeyer.com

* Monday - Thursday 7.30 - 16.00
Friday 7.30 - 13.00